Resultados 1 - 20 de 1.448
Filtrar
1.
NMR Biomed ; 37(4): e5091, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38196195

RESUMO

BACKGROUND: Despite the widespread use of cine MRI for evaluation of cardiac function, existing real-time methods do not easily enable quantification of ventricular function. Moreover, segmented cine MRI assumes periodicity of cardiac motion. We aim to develop a self-gated, cine MRI acquisition scheme with data-driven cluster-based binning of cardiac motion. METHODS: A Cartesian golden-step balanced steady-state free precession sequence with sorted k-space ordering was designed. Image data were acquired with breath-holding. Principal component analysis and k-means clustering were used for binning of cardiac phases. Cluster compactness in the time dimension was assessed using temporal variability, and dispersion in the spatial dimension was assessed using the Calinski-Harabasz index. The proposed and the reference electrocardiogram (ECG)-gated cine methods were compared using a four-point image quality score, SNR and CNR values, and Bland-Altman analyses of ventricular function. RESULTS: A total of 10 subjects with sinus rhythm and 8 subjects with arrhythmias underwent cardiac MRI at 3.0 T. The temporal variability was 45.6 ms (cluster) versus 24.6 ms (ECG-based) (p < 0.001), and the Calinski-Harabasz index was 59.1 ± 9.1 (cluster) versus 22.0 ± 7.1 (ECG based) (p < 0.001). In subjects with sinus rhythm, 100% of the end-systolic and end-diastolic images from both the cluster and reference approach received the highest image quality score of 4. Relative to the reference cine images, the cluster-based multiphase (cine) image quality consistently received a one-point lower score (p < 0.05), whereas the SNR and CNR values were not significantly different (p = 0.20). In cases with arrhythmias, 97.9% of the end-systolic and end-diastolic images from the cluster approach received an image quality score of 3 or more. The mean bias values for biventricular ejection fraction and volumes derived from the cluster approach versus reference cine were negligible. CONCLUSION: ECG-free cine cardiac MRI with data-driven clustering for binning of cardiac motion is feasible and enables quantification of cardiac function.


Assuntos
Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Técnicas de Imagem de Sincronização Cardíaca/métodos , Função Ventricular , Análise por Conglomerados , Reprodutibilidade dos Testes
2.
Int J Cardiovasc Imaging ; 40(1): 93-105, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37874445

RESUMO

This study aims to evaluate the accuracy and reliability of the cardiac and respiratory signals extracted from Pilot Tone (PT) in patients clinically referred for cardiovascular MRI. Twenty-three patients were scanned under free-breathing conditions using a balanced steady-state free-precession real-time (RT) cine sequence on a 1.5T scanner. The PT signal was generated by a built-in PT transmitter integrated within the body array coil, and retrospectively processed to extract respiratory and cardiac signals. For comparison, ECG and BioMatrix (BM) respiratory sensor signals were also synchronously recorded. To assess the performances of PT, ECG, and BM, cardiac and respiratory signals extracted from the RT cine images were used as the ground truth. The respiratory motion extracted from PT correlated positively with the image-derived respiratory signal in all cases and showed a stronger correlation (absolute coefficient: 0.95 ± 0.09) than BM (0.72 ± 0.24). For the cardiac signal, PT trigger jitter (standard deviation of PT trigger locations relative to ECG triggers) ranged from 6.6 to 83.3 ms, with a median of 21.8 ms. The mean absolute difference between the PT and corresponding ECG cardiac cycle duration was less than 5% of the average ECG RR interval for 21 out of 23 patients. We did not observe a significant linear dependence (p > 0.28) of PT delay and PT jitter on the patients' BMI or cardiac cycle duration. This study demonstrates the potential of PT to monitor both respiratory and cardiac motion in patients clinically referred for cardiovascular MRI.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Imagem Cinética por Ressonância Magnética , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Valor Preditivo dos Testes , Imageamento por Ressonância Magnética , Movimento (Física)
3.
Eur Radiol ; 33(2): 1254-1265, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36098798

RESUMO

OBJECTIVES: To validate an artificial intelligence (AI)-based fully automatic coronary artery calcium (CAC) scoring system on non-electrocardiogram (ECG)-gated low-dose chest computed tomography (LDCT) using multi-institutional datasets with manual CAC scoring as the reference standard. METHODS: This retrospective study included 452 subjects from three academic institutions, who underwent both ECG-gated calcium scoring computed tomography (CSCT) and LDCT scans. For all CSCT and LDCT scans, automatic CAC scoring (CAC_auto) was performed using AI-based software, and manual CAC scoring (CAC_man) was set as the reference standard. The reliability and agreement of CAC_auto was evaluated and compared with that of CAC_man using intraclass correlation coefficients (ICCs) and Bland-Altman plots. The reliability between CAC_auto and CAC_man for CAC severity categories was analyzed using weighted kappa (κ) statistics. RESULTS: CAC_auto on CSCT and LDCT yielded a high ICC (0.998, 95% confidence interval (CI) 0.998-0.999 and 0.989, 95% CI 0.987-0.991, respectively) and a mean difference with 95% limits of agreement of 1.3 ± 37.1 and 0.8 ± 75.7, respectively. CAC_auto achieved excellent reliability for CAC severity (κ = 0.918-0.972) on CSCT and good to excellent but heterogenous reliability among datasets (κ = 0.748-0.924) on LDCT. CONCLUSIONS: The application of an AI-based automatic CAC scoring software to LDCT shows good to excellent reliability in CAC score and CAC severity categorization in multi-institutional datasets; however, the reliability varies among institutions. KEY POINTS: • AI-based automatic CAC scoring on LDCT shows excellent reliability with manual CAC scoring in multi-institutional datasets. • The reliability for CAC score-based severity categorization varies among datasets. • Automatic scoring for LDCT shows a higher false-positive rate than automatic scoring for CSCT, and most common causes of a false-positive are image noise and artifacts for both CSCT and LDCT.


Assuntos
Cálcio , Técnicas de Imagem de Sincronização Cardíaca , Vasos Coronários , Tomografia Computadorizada por Raios X , Humanos , Inteligência Artificial , Cálcio/análise , Técnicas de Imagem de Sincronização Cardíaca/métodos , Vasos Coronários/diagnóstico por imagem , Conjuntos de Dados como Assunto , Eletrocardiografia , Estudos Multicêntricos como Assunto , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
4.
Acta Radiol ; 64(5): 2024-2032, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36451522

RESUMO

BACKGROUND: Redoable precise and non-invasive diagnostic imaging modality with the least radiation dose is essential for infants with congenital heart disease (CHD) . PURPOSE: To investigate the accuracy and estimate the radiation dose of our cardiac computed tomography (CCT) protocol. MATERIAL AND METHODS: A total of 82 infants with CHD underwent non-ECG-gated CCT without contrast timing scanning techniques and were retrospectively studied. The image quality and radiation dose were estimated. The radiation dose was compared statistically to virtual retrospective ECG-gated and prospective ECG-triggering scanning modes. The diagnostic accuracy was assessed assuming the surgical results as the diagnostic gold standard. RESULTS: Most exams showed a high quality with low radiation doses compared to previous studies. The mean effective dose (ED) was 0.39 ± 1.2, significantly lower than that of the virtual retrospective ECG-gated and prospective ECG-triggering scanning and lower than in previous studies. Our CCT protocol has achieved a diagnostic accuracy of 99.52% with a sensitivity of 94.83% and specificity of 99.91%. CONCLUSION: Non-ECG-gated CCT without contrast timing techniques can detect the non-coronary cardiovascular defects of CHD in infants with an ultralow radiation dose and a high diagnostic accuracy.


Assuntos
Cardiopatias Congênitas , Tomografia Computadorizada Multidetectores , Lactente , Humanos , Estudos Retrospectivos , Estudos Prospectivos , Doses de Radiação , Angiografia Coronária/métodos , Tomografia Computadorizada Multidetectores/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Eletrocardiografia , Técnicas de Imagem de Sincronização Cardíaca/métodos
5.
Tomography ; 8(5): 2426-2434, 2022 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-36287800

RESUMO

Rationale and Objective: Thoracic CT angiography (CTA) for ascending aortic dissection, a life-threatening emergency, is performed routinely without Electrocardiographic (ECG) gating, therefore allowing the apparition of a pulsation artefact. We aimed to evaluate and compare the diagnostic performance, the inter and intra-reporter agreement of ECG gated CTA and non-ECG gated CTA for detecting ascending aortic dissection, considering their training level. Our hypothesis is that ECG gated CTA has superior diagnostic accuracy for ascending aortic dissection compared to non-gated CTA. Materials and Methods: We collected data using 24 questions survey using clinically validated CT examinations. Sixty-six respondents (medical students, radiology residents, and consultants) blinded to the actual diagnosis independently evaluated the images pertaining to the presence of ascending aortic dissection. The reference standard was represented by clinical and imaging diagnosis. Inter-rater and inter-group concordance was evaluated; the agreement with reference tests was calculated and assessed as a function of reporters' training level. Results: Reporters' ascending aortic dissection assessment showed a better correlation with the reference standard in the ECG gated CTA. The inter-rater correlation was higher in the ECG gated CTA compared to non-ECG gated CTA. Observers' confidence for diagnosing ascending aortic dissection was higher in the ECG gated CTA. Statistically significant differences (p < 0.05) were found between different training levels when assessing non-ECG gated examinations. Conclusions: ECG gated CTA shows a higher diagnostic performance for ascending aortic dissection than non-ECG gated CTA, regardless of the reporters' training level.


Assuntos
Dissecção Aórtica , Angiografia por Tomografia Computadorizada , Humanos , Angiografia por Tomografia Computadorizada/métodos , Técnicas de Imagem de Sincronização Cardíaca/métodos , Eletrocardiografia/métodos , Angiografia/métodos , Dissecção Aórtica/diagnóstico por imagem
6.
Zhonghua Xin Xue Guan Bing Za Zhi ; 50(8): 805-810, 2022 Aug 24.
Artigo em Chinês | MEDLINE | ID: mdl-35982014

RESUMO

Objective: To investigate the dynamic change of the secundum atrial septal defect (ASD) throughout the cardiac cycle, and assess its impact on occluder selection. Methods: This study retrospectively analyzed 35 patients with ASD who received electrocardiogram-gated coronary CT angiography (CCTA) throughout the cardiac cycle as well as interventional closure therapy in Fuwai Hospital from December 2016 to December 2019. The raw data were reconstructed into 20 phasic images of RR intervals (RRI) ranging from 0 to 95% in an increment of 5% and transmitted to a workstation for postprocessing. For each phase image, CT virtual endoscopy reconstruction technique (CTVE) was used to provide views of ASD. Axial sequence assisted CT volumetric measurement (CTAS) was used to calculate the maximum dimensions in axial planes (Da) and in superior-inferior direction (Db). Using a formula for converting circumference to diameter, the equivalent circle dimensions were calculated (De, De=minor axis+2 (major axis-minor axis)/3). Taking the data of 75% RRI phase, the patients were divided into Da75%RRI≥Db75%RRI group and Da75%RRIDa. Db is basically constant while Da changes significantly during cardiac cycle (10%-90% RRI). Nonetheless, both values peak and maintain the maximum status at end-systolic phase (35%-45% RRI). For patients with huge ASD, occluder selection should be based on the De at 35% RRI phase, which is helpful for the successful intervention.


Assuntos
Comunicação Interatrial , Dispositivo para Oclusão Septal , Adulto , Técnicas de Imagem de Sincronização Cardíaca , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Eletrocardiografia/métodos , Feminino , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/cirurgia , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
7.
N Engl J Med ; 387(15): 1385-1394, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-36027560

RESUMO

BACKGROUND: Limited data suggest a benefit of population-based screening for cardiovascular disease with respect to the risk of death. METHODS: We performed a population-based, parallel-group, randomized, controlled trial involving men 65 to 74 years of age living in 15 Danish municipalities. The participants were randomly assigned in a 1:2 ratio to undergo screening (the invited group) or not to undergo screening (the control group) for subclinical cardiovascular disease. Randomization was based on computer-generated random numbers and stratified according to municipality. Only the control group was unaware of the trial-group assignments. Screening included noncontrast electrocardiography-gated computed tomography to determine the coronary-artery calcium score and to detect aneurysms and atrial fibrillation, ankle-brachial blood-pressure measurements to detect peripheral artery disease and hypertension, and a blood sample to detect diabetes mellitus and hypercholesterolemia. The primary outcome was death from any cause. RESULTS: A total of 46,611 participants underwent randomization. After exclusion of 85 men who had died or emigrated before being invited to undergo screening, there were 16,736 men in the invited group and 29,790 men in the control group; 10,471 of the men in the invited group underwent screening (62.6%). In intention-to-treat analyses, after a median follow-up of 5.6 years, 2106 men (12.6%) in the invited group and 3915 men (13.1%) in the control group had died (hazard ratio, 0.95; 95% confidence interval [CI], 0.90 to 1.00; P = 0.06). The hazard ratio for stroke in the invited group, as compared with the control group, was 0.93 (95% CI, 0.86 to 0.99); for myocardial infarction, 0.91 (95% CI, 0.81 to 1.03); for aortic dissection, 0.95 (95% CI, 0.61 to 1.49); and for aortic rupture, 0.81 (95% CI, 0.49 to 1.35). There were no significant between-group differences in safety outcomes. CONCLUSIONS: After more than 5 years, the invitation to undergo comprehensive cardiovascular screening did not significantly reduce the incidence of death from any cause among men 65 to 74 years of age. (Funded by the Southern Region of Denmark and others; DANCAVAS ISRCTN Registry number, ISRCTN12157806.).


Assuntos
Doenças Cardiovasculares , Programas de Rastreamento , Humanos , Masculino , Cálcio/análise , Dinamarca/epidemiologia , Incidência , Programas de Rastreamento/métodos , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/epidemiologia , Idoso , Técnicas de Imagem de Sincronização Cardíaca , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/epidemiologia
8.
Magn Reson Imaging ; 92: 161-168, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35777685

RESUMO

To explore and extend on dynamic imaging of joint motion, an MRI-safe device guiding knee motion with an attached rotary encoder was used in MRI measurements of multiple knee flexion-extension cycles using radial gradient echo imaging with the golden-angle as azimuthal angle increment. Reproducibility of knee motion was investigated. Real-time and CINE mode anatomical images were reconstructed for different knee flexion angles by synchronizing the encoder information with the MRI data, and performing flexion angle selective gating across multiple motion cycles. When investigating the influence of the rotation angle window width on reconstructed CINE images, it was found that angle windows between 0.5° and 3° exhibited acceptable image sharpness without suffering from significant motion-induced blurring. Furthermore, due to flexible retrospective image reconstruction afforded by the radial golden-angle imaging, the number of motion cycles included in the reconstruction could be retrospectively reduced to investigate the corresponding influence of acquisition time on image quality. Finally, motion reproducibility between motion cycles and accuracy of the flexion angle selective gating were sufficient to acquire whole-knee 3D dynamic imaging with a retrospectively gated 3D cone UTE sequence.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Interpretação de Imagem Assistida por Computador , Técnicas de Imagem de Sincronização Cardíaca/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos
9.
J Cardiovasc Comput Tomogr ; 16(4): 345-349, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34949532

RESUMO

BACKGROUND: Advances in cardiac CT (CCT) scanner technology allow imaging without anesthesia, and with low radiation dose, making it an attractive technique in infants with congenital heart disease. However, the utility of CCT using a dual-source scanner with respect to diagnostic performance and impact on management has not been systematically studied in this population. METHODS: Retrospective review of infants who underwent CCT to determine the utility of CCT with respect to the following: answering the primary diagnostic question, providing new diagnostic information, prompting a change in management, and concordance with catheterization or surgical inspection. RESULTS: A total of 156 infants underwent 172 scans at a median age of 64 days, (IQR 4-188) from Jan 2016-Dec 2019. The most frequent diagnostic question was related to the pulmonary arteries (43%), followed by the aortic arch (30%), pulmonary veins (26%), coronary arteries (17%), patent ductus arteriosus (10%) and others (9%). A high-pitch spiral scan was frequently used (90%). The median effective radiation dose was low (0.66 â€‹mSv) and general anesthesia was used infrequently (23%). CCT answered the primary diagnostic question in 168/172 (98%) and added to the diagnostic information already available by echocardiography in 161/172 (96%) scans. CCT led to a change in management following 78/172 (53%) scans and had an impact on management following 167/172 (97%) scans. On follow-up, after 107/172 (62%) scans, subjects underwent cardiac surgery, and after 55/172 (32%) scans, they had cardiac catheterization. CCT findings were concordant with catheterization and/or surgical inspection in 156/159 (98%) scans. CONCLUSIONS: In infants with complex congenital heart disease, CCT was accurate, answered the diagnostic questions in nearly all cases, and frequently added diagnostic information that impacted management. Radiation exposure was low, and anesthesia was needed infrequently.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Cardiopatias Congênitas , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Humanos , Lactente , Valor Preditivo dos Testes , Doses de Radiação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
10.
Pacing Clin Electrophysiol ; 45(1): 72-82, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34820857

RESUMO

AIMS: Neither the long-term development of ablation lesions nor the capability of late gadolinium enhancement (LGE)-MRI to detect ablation-induced fibrosis at late stages of scar formation have been defined. We sought to assess the development of atrial ablation lesions over time using LGE-MRI and invasive electroanatomical mapping (EAM). METHODS AND RESULTS: Ablation lesions and total atrial fibrosis were assessed in serial LGE-MRI scans 3 months and >12 months post pulmonary vein (PV) isolation. High-density EAM performed in subsequent repeat ablation procedures served as a reference. Serial LGE-MRI of 22 patients were analyzed retrospectively. The PV encircling ablation lines displayed an average LGE, indicative of ablation-induced fibrosis, of 91.7% ± 7.0% of the circumference at 3 months, but only 62.8% ± 25.0% at a median of 28 months post ablation (p < 0.0001). EAM performed in 18 patients undergoing a subsequent repeat procedure revealed that the consistent decrease in LGE over time was owed to a reduced detectability of ablation-induced fibrosis by LGE-MRI at time-points > 12 months post ablation. Accordingly, the agreement with EAM regarding detection of ablation-induced fibrosis and functional gaps was good for the LGE-MRI at 3 months (κ .74; p < .0001), but only weak for the LGE-MRI at 28 months post-ablation (κ .29; p < .0001). CONCLUSION: While non-invasive lesion assessment with LGE-MRI 3 months post ablation provides accurate guidance for future redo-procedures, detectability of atrial ablation lesions appears to decrease over time. Thus, it should be considered to perform LGE-MRI 3 months post-ablation rather than at later time-points > 12 months post ablation, like for example, prior to a planned redo-ablation procedure.


Assuntos
Fibrilação Atrial/cirurgia , Cicatriz/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Técnicas de Imagem de Sincronização Cardíaca , Cicatriz/etiologia , Meios de Contraste , Técnicas Eletrofisiológicas Cardíacas , Feminino , Fibrose/diagnóstico por imagem , Fibrose/etiologia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos , Complicações Pós-Operatórias/etiologia , Veias Pulmonares/cirurgia , Recidiva , Sistema de Registros , Estudos Retrospectivos , Espanha
11.
Acta Radiol ; 63(1): 133-140, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33423530

RESUMO

BACKGROUND: Deep learning (DL) has achieved great success in medical imaging and could be utilized for the non-invasive calculation of fractional flow reserve (FFR) from coronary computed tomographic angiography (CCTA) (CT-FFR). PURPOSE: To examine the ability of a DL-based CT-FFR in detecting hemodynamic changes of stenosis. MATERIAL AND METHODS: This study included 73 patients (85 vessels) who were suspected of coronary artery disease (CAD) and received CCTA followed by invasive FFR measurements within 90 days. The diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and area under the receiver operating characteristics curve (AUC) were compared between CT-FFR and CCTA. Thirty-nine patients who received drug therapy instead of revascularization were followed for up to 31 months. Major adverse cardiac events (MACE), unstable angina, and rehospitalization were evaluated and compared between the study groups. RESULTS: At the patient level, CT-FFR achieved 90.4%, 93.6%, 88.1%, 85.3%, and 94.9% in accuracy, sensitivity, specificity, PPV, and NPV, respectively. At the vessel level, CT-FFR achieved 91.8%, 93.9%, 90.4%, 86.1%, and 95.9%, respectively. CT-FFR exceeded CCTA in these measurements at both levels. The vessel-level AUC for CT-FFR also outperformed that for CCTA (0.957 vs. 0.599, P < 0.0001). Patients with CT-FFR ≤0.8 had higher rates of rehospitalization (hazard ratio [HR] 4.51, 95% confidence interval [CI] 1.08-18.9) and MACE (HR 7.26, 95% CI 0.88-59.8), as well as a lower rate of unstable angina (HR 0.46, 95% CI 0.07-2.91). CONCLUSION: CT-FFR is superior to conventional CCTA in differentiating functional myocardial ischemia. In addition, it has the potential to differentiate prognoses of patients with CAD.


Assuntos
Angiografia por Tomografia Computadorizada , Estenose Coronária/diagnóstico por imagem , Aprendizado Profundo , Reserva Fracionada de Fluxo Miocárdico , Adulto , Idoso , Idoso de 80 Anos ou mais , Técnicas de Imagem de Sincronização Cardíaca , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
12.
BMC Med Imaging ; 21(1): 161, 2021 10 31.
Artigo em Inglês | MEDLINE | ID: mdl-34719378

RESUMO

BACKGROUND: To assess the accuracy and reproducibility of right ventricular (RV) and left ventricular (LV) function and flow measurements in children with repaired tetralogy of Fallot (rTOF) using four-dimensional (4D) flow, compared with conventional two-dimensional (2D) magnetic resonance imaging (MRI) sequences. METHODS: Thirty pediatric patients with rTOF were retrospectively enrolled to undergo 2D balanced steady-state free precession cine (2D b-SSFP cine), 2D phase contrast (PC), and 4D flow cardiac MRI. LV and RV volumes and flow in the ascending aorta (AAO) and main pulmonary artery (MPA) were quantified. Pearson's or Spearman's correlation tests, paired t-tests, the Wilcoxon signed-rank test, Bland-Altman analysis, and intraclass correlation coefficients (ICC) were performed. RESULTS: The 4D flow scan time was shorter compared with 2D sequences (P < 0.001). The biventricular volumes between 4D flow and 2D b-SSFP cine had no significant differences (P > 0.05), and showed strong correlations (r > 0.90, P < 0.001) and good consistency. The flow measurements of the AAO and MPA between 4D flow and 2D PC showed moderate to good correlations (r > 0.60, P < 0.001). There was good internal consistency in cardiac output. There was good intraobserver and interobserver biventricular function agreement (ICC > 0.85). CONCLUSIONS: RV and LV function and flow quantification in pediatric patients with rTOF using 4D flow MRI can be measured accurately and reproducibly compared to those with conventional 2D sequences.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Tetralogia de Fallot/cirurgia , Velocidade do Fluxo Sanguíneo , Técnicas de Imagem de Sincronização Cardíaca , Criança , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Função Ventricular Esquerda , Função Ventricular Direita
13.
Br J Radiol ; 94(1123): 20210048, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34111982

RESUMO

OBJECTIVES: Magnetic resonance angiography (MRA) has been established as an important imaging method in cardiac ablation procedures. In pulmonary vein (PV) isolation procedures, MRA has the potential to minimize the risk of severe complications, such as atrio-esophageal fistula, by providing detailed information on esophageal position relatively to cardiac structures. However, traditional non-gated, first-pass (FP) MRA approaches have several limitations, such as long breath-holds, non-uniform signal intensity throughout the left atrium (LA), and poor esophageal visualization. The aim of this observational study was to validate a respiratory-navigated, ECG-gated (EC), saturation recovery-prepared MRA technique for simultaneous imaging of LA, LA appendage, PVs, esophagus, and adjacent anatomical structures. METHODS: Before PVI, 106 consecutive patients with a history of AF underwent either conventional FP-MRA (n = 53 patients) or our new EC-MRA (n = 53 patients). Five quality scores (QS) of LA and esophagus visibility were assessed by two experienced readers. The non-parametric Mann-Whitney U-test was used to compare QS between FP-MRA and EC-MRA groups, and linear regression was applied to assess clinical contributors to image quality. RESULTS: EC-MRA demonstrated significantly better image quality than FP-MRA in every quality category. Esophageal visibility using the new MRA technique was markedly better than with the conventional FP-MRA technique (median 3.5 [IQR 1] vs median 1.0, p < 0.001). In contrast to FP-MRA, overall image quality of EC-MRA was not influenced by heart rate. CONCLUSION: Our ECG-gated, respiratory-navigated, saturation recovery-prepared MRA technique provides significantly better image quality and esophageal visibility than the established non-gated, breath-holding FP-MRA. Image quality of EC-MRA technique has the additional advantage of being unaffected by heart rate. ADVANCES IN KNOWLEDGE: Detailed information of cardiac anatomy has the potential to minimize the risk of severe complications and improve success rates in invasive electrophysiological studies. Our novel ECG-gated, respiratory-navigated, saturation recovery-prepared MRA technique provides significantly better image quality of LA and esophageal structures than the traditional first-pass algorithm. This new MRA technique is robust to arrhythmia (tachycardic, irregular heart rates) frequently observed in AF patients.


Assuntos
Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Esôfago/diagnóstico por imagem , Átrios do Coração/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Veias Pulmonares/diagnóstico por imagem , Suspensão da Respiração , Técnicas de Imagem de Sincronização Cardíaca , Meios de Contraste , Feminino , Humanos , Masculino , Meglumina/análogos & derivados , Pessoa de Meia-Idade , Compostos Organometálicos , Técnicas de Imagem de Sincronização Respiratória
14.
J Comput Assist Tomogr ; 45(3): 415-420, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33797443

RESUMO

OBJECTIVES: The aim of this study was to determine the difference and correlation in pulmonary artery (PA) size when measured from the electrocardiogram (ECG)-gated computed tomography (CT) and non-ECG-gated CT. METHODS: In the retrospective study, 279 patients who underwent both ECG-gated CT and non-ECG-gated CT were enrolled. Maximum and minimum diameters of main pulmonary artery (MPA), right pulmonary artery (RPA), and ascending aorta (AAO) were measured, whereas mean diameters of MPA and RPA were obtained. The same PA size parameters were also measured on non-ECG-gated CT. RESULTS: There was a significant difference in maximum and minimum PA diameters between ECG-gated CT and non-ECG-gated CT, whereas mean PA diameters showed no statistically difference. The PA parameters showed a strong positive correlation between these 2 examinations. CONCLUSIONS: The PA size was different between ECG-gated CT and non-ECG-gated CT, whereas the PA size parameters on non-ECG-gated CT could be used to predict those with ECG-gated CT, which allow for confident prediction of pulmonary hypertension and guide further surgical intervention.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Hipertensão Pulmonar/diagnóstico por imagem , Artéria Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Eletrocardiografia , Feminino , Cardiopatias Congênitas/patologia , Cardiopatias Congênitas/fisiopatologia , Humanos , Hipertensão Pulmonar/patologia , Hipertensão Pulmonar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Artéria Pulmonar/patologia , Artéria Pulmonar/fisiopatologia , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
15.
Magn Reson Imaging ; 81: 1-9, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33905831

RESUMO

Prospective cardiac gating during MRI is hampered by electromagnetic induction from the rapidly switched imaging gradients into the ECG detection circuit. This is particularly challenging in small animal MRI, as higher heart rates combined with a smaller myocardial mass render routine ECG detection challenging. We have developed an open-hardware system that enables continuously running MRI scans to be performed in conjunction with cardio-respiratory gating such that the relaxation-weighted steady state magnetisation is maintained throughout the scan. This requires that the R-wave must be detected reliably even in the presence of rapidly switching gradients, and that data previously acquired that were corrupted by respiratory motion re-acquired. The accurately maintained steady-state magnetisation leads to an improvement in image quality and removes alterations in intensity that may otherwise occur throughout the cardiac cycle and impact upon automated image analysis. We describe the hardware required to enable this and demonstrate its application and robust performance using prospectively cardio-respiratory gated CINE imaging that is operated at a single, constant TR. Schematics, technical drawings, component listing and assembly instructions are made publicly available.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Imagem Cinética por Ressonância Magnética , Animais , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Estudos Prospectivos
16.
Magn Reson Imaging ; 81: 42-52, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33905835

RESUMO

PURPOSE: To develop and validate a new cardiac self-gating algorithm using blind source separation for 2D cine steady-state free precession (SSFP) imaging. METHODS: A standard cine SSFP sequence was modified so that the center point of k-space was sampled with each excitation. The center points of k-space were processed by 4 blind source separation methods, and used to detect heartbeats and assign k-space data to appropriate time points in the cardiac cycle. The proposed self-gating technique was prospectively validated in 8 patients against the standard electrocardiogram (ECG)-gating method by comparing the cardiac cycle lengths, image quality metrics, and ventricular volume measurements. RESULTS: There was close agreement between the cardiac cycle length using the ECG- and self-gating methods (bias 0.0 bpm, 95% limits of agreement ±2.1 bpm). The image quality metrics were not significantly different between the ECG- and self-gated images. The ventricular volumes, stroke volumes, and mass measured from self-gated images were all comparable with those from ECG-gated images (all biases <5%). CONCLUSION: The self-gating method yielded comparable cardiac cycle length, image quality, and ventricular measurements compared with standard ECG-gated cine imaging. It may simplify patient preparation, be more robust when there is arrhythmia, and allow cardiac gating at higher field strengths.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Interpretação de Imagem Assistida por Computador , Algoritmos , Coração/diagnóstico por imagem , Humanos , Imagem Cinética por Ressonância Magnética
17.
J Cardiovasc Magn Reson ; 23(1): 33, 2021 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-33775246

RESUMO

BACKGROUND: Radial self-navigated (RSN) whole-heart coronary cardiovascular magnetic resonance angiography (CCMRA) is a free-breathing technique that estimates and corrects for respiratory motion. However, RSN has been limited to a 1D rigid correction which is often insufficient for patients with complex respiratory patterns. The goal of this work is therefore to improve the robustness and quality of 3D radial CCMRA by incorporating both 3D motion information and nonrigid intra-acquisition correction of the data into a framework called focused navigation (fNAV). METHODS: We applied fNAV to 500 data sets from a numerical simulation, 22 healthy subjects, and 549 cardiac patients. In each of these cohorts we compared fNAV to RSN and respiratory resolved extradimensional golden-angle radial sparse parallel (XD-GRASP) reconstructions of the same data. Reconstruction times for each method were recorded. Motion estimate accuracy was measured as the correlation between fNAV and ground truth for simulations, and fNAV and image registration for in vivo data. Percent vessel sharpness was measured in all simulated data sets and healthy subjects, and a subset of patients. Finally, subjective image quality analysis was performed by a blinded expert reviewer who chose the best image for each in vivo data set and scored on a Likert scale 0-4 in a subset of patients by two reviewers in consensus. RESULTS: The reconstruction time for fNAV images was significantly higher than RSN (6.1 ± 2.1 min vs 1.4 ± 0.3, min, p < 0.025) but significantly lower than XD-GRASP (25.6 ± 7.1, min, p < 0.025). Overall, there is high correlation between the fNAV and reference displacement estimates across all data sets (0.73 ± 0.29). For simulated data, healthy subjects, and patients, fNAV lead to significantly sharper coronary arteries than all other reconstruction methods (p < 0.01). Finally, in a blinded evaluation by an expert reviewer fNAV was chosen as the best image in 444 out of 571 data sets (78%; p < 0.001) and consensus grades of fNAV images (2.6 ± 0.6) were significantly higher (p < 0.05) than uncorrected (1.7 ± 0.7), RSN (1.9 ± 0.6), and XD-GRASP (1.8 ± 0.8). CONCLUSION: fNAV is a promising technique for improving the quality of RSN free-breathing 3D whole-heart CCMRA. This novel approach to respiratory self-navigation can derive 3D nonrigid motion estimations from an acquired 1D signal yielding statistically significant improvement in image sharpness relative to 1D translational correction as well as XD-GRASP reconstructions. Further study of the diagnostic impact of this technique is therefore warranted to evaluate its full clinical utility.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador , Angiografia por Ressonância Magnética , Adulto , Idoso , Estudos de Casos e Controles , Simulação por Computador , Doença das Coronárias/fisiopatologia , Vasos Coronários/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Movimento , Análise Numérica Assistida por Computador , Valor Preditivo dos Testes , Respiração , Adulto Jovem
18.
J Cardiovasc Magn Reson ; 23(1): 8, 2021 02 11.
Artigo em Inglês | MEDLINE | ID: mdl-33568177

RESUMO

BACKGROUND: Extracellular volume fraction (ECV) quantification with cardiovascular magnetic resonance (CMR) T1 mapping is a powerful tool for the characterization of focal or diffuse myocardial fibrosis. However, it is technically challenging to acquire high-quality T1 and ECV maps in small animals for preclinical research because of high heart rates and high respiration rates. In this work, we developed an electrocardiogram (ECG)-less, free-breathing ECV mapping method using motion-resolved CMR Multitasking on a 9.4 T small animal CMR system. The feasibility of characterizing diffuse myocardial fibrosis was tested in a rat heart failure model with preserved ejection fraction (HFpEF). METHODS: High-salt fed rats diagnosed with HFpEF (n = 9) and control rats (n = 9) were imaged with the proposed ECV Multitasking technique. A 25-min exam, including two 4-min T1 Multitasking scans before and after gadolinium injection, were performed on each rat. It allows a cardiac temporal resolution of 20 ms for a heart rate of ~ 300 bpm. Myocardial ECV was calculated from the hematocrit (HCT) and fitted T1 values of the myocardium and the blood pool. Masson's trichrome stain was used to measure the extent of fibrosis. Welch's t-test was performed between control and HFpEF groups. RESULTS: ECV was significantly higher in the HFpEF group (22.4% ± 2.5% vs. 18.0% ± 2.1%, P = 0.0010). A moderate correlation between the ECV and the extent of fibrosis was found (R = 0.59, P = 0.0098). CONCLUSIONS: Motion-resolved ECV Multitasking CMR can quantify ECV in the rat myocardium at high heart rates without ECG triggering or respiratory gating. Elevated ECV found in the HFpEF group is consistent with previous human studies and well correlated with histological data. This technique has the potential to be a viable imaging tool for myocardial tissue characterization in small animal models.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Insuficiência Cardíaca/diagnóstico por imagem , Frequência Cardíaca , Imageamento por Ressonância Magnética , Respiração , Volume Sistólico , Função Ventricular Esquerda , Animais , Modelos Animais de Doenças , Estudos de Viabilidade , Fibrose , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Hipertensão/etiologia , Hipertensão/fisiopatologia , Masculino , Miocárdio/patologia , Valor Preditivo dos Testes , Ratos Endogâmicos Dahl , Cloreto de Sódio na Dieta
19.
J Nucl Cardiol ; 28(6): 2545-2556, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-32060856

RESUMO

PURPOSE: The objective of this study was to assess the incremental value of myocardial wall motion and thickening compared with perfusion alone obtained from gated single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) in diagnosing myocardial viability in patients with ischemic heart failure. METHODS: Eighty-three consecutive patients with ischemic heart failure who underwent both 99mTc-MIBI gated SPECT MPI and 18F-FDG positron emission tomography (PET) myocardial metabolic imaging were retrospectively enrolled. SPECT/PET myocardial viability was defined as the reference standard. Segmental myocardial perfusion, wall motion, and thickening were measured by an automated algorithm from gated SPECT MPI. Univariate and stepwise multivariate analysis were conducted to establish an optimal multivariate model for predicting hibernating myocardium and scar. RESULTS: Among the 1411 segments evaluated, 774 segments had normal perfusion and 637 segments had decreased perfusion. The latter were classified by 18F-FDG PET into 338 hibernating segments and 299 scarred segments. The multivariate regression analysis showed that the model that combined myocardial perfusion uptake with wall motion and thickening scores had the optimal predictive efficiency to distinguish hibernating myocardium from scar in the segments with decreased perfusion. The model had the largest C-statistic (0.753 vs 0.666, P < 0.0001), and the global chi-square was increased from 53.281 to 111.234 when compared with perfusion alone (P < 0.001). CONCLUSIONS: Assessment of myocardial wall motion and thickening in addition to conventional perfusion uptake in the segments with decreased perfusion enables better differentiation of hibernating myocardium from scar in patients with ischemic heart failure. Considering wide availability and high cost-effectiveness, regional myocardial function integrated with perfusion on gated SPECT MPI has great promise to become a clinical tool in the assessment of myocardial viability.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Coração/fisiopatologia , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/fisiopatologia , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Feminino , Insuficiência Cardíaca/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/complicações , Miocárdio/patologia , Estudos Retrospectivos
20.
Int J Cardiovasc Imaging ; 37(2): 509-515, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32959097

RESUMO

Regadenoson Stress Echocardiography (RSE) can detect myocardial ischemia, and its diagnostic accuracy should be evaluated. We sought to investigate the agreement between RSE and gated-SPECT myocardial perfusion imaging (MPI) and appraise its diagnostic accuracy. Consecutive patients (n = 202) referred for non-invasive evaluation of myocardial ischemia, with (38.6%) or without a previous coronary artery disease (CAD) diagnosis, were enrolled. Both tests were performed simultaneously. Invasive coronary angiography (CA) is considered the gold standard. The mean age was 70.9 (9.8) years, and 59.9% were male. The prevalence of cardiovascular risk factors (arterial hypertension [81.7%], diabetes mellitus [37.6%], hypercholesterolemia [71.8%], and smoking [18.8%]) was high. Forty-four patients (21.8%) had a non-interpretable electrocardiogram, 15 (34.1%) of them were a result of ventricular paced-rhythm, while 29 (65.9%) were a result of advanced left ventricular branch block. The overall agreement between both diagnostic techniques was good: Gwet's AC1 0.66 (CI95% 0.55 to 0.76), and it was higher in patients without a previous CAD diagnosis: 0.76 (CI95% 0.65 to 0.87). In the biased sample (those who underwent CA), RSE and nuclear study sensitivity was 0.50 and 0.78 and specificity was 0.75 and 0.75, respectively. We noted a dramatic reduction in sensitivity for RSE after debiasing (debiased sensitivity of 0.16), and the negative predictive value was similar to the biased and debiased samples. RSE is in strong agreement with gated-SPECT MPI. However, its low sensitivity and negative predictive value preclude its use as a bedside test to detect myocardial ischemia.


Assuntos
Ecocardiografia sob Estresse , Isquemia Miocárdica/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Purinas , Pirazóis , Tomografia Computadorizada de Emissão de Fóton Único , Vasodilatadores , Idoso , Técnicas de Imagem de Sincronização Cardíaca , Comorbidade , Feminino , Fatores de Risco de Doenças Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/epidemiologia , Isquemia Miocárdica/fisiopatologia , Compostos Organofosforados , Compostos de Organotecnécio , Valor Preditivo dos Testes , Prevalência , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Fumar/efeitos adversos , Fumar/epidemiologia , Tecnécio Tc 99m Sestamibi
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...